Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.45 g/cm³ |
Water absorption rate | | ASTM D570 | 1.5 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
bending strength | | ASTM D790 | 130 MPa |
bending strength | | ASTM D790 | 92.4 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 26 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 28 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
High Voltage Arc Traceability Rate (HVTR) | | UL 746 | PLC 0 mm/min |
Hot wire ignition (HWI) | | UL 746 | PLC 1 sec |
dielectric strength | | ASTM D149 | 45000 V |
dielectric strength | | ASTM D149 | >18 kV/mm |
arc resistance | | ASTM D495 | 123 sec |
Compared to the Leakage Tracking Index (CTI) | | UL 746 | PLC 1 |
High arc combustion index (HAI) | | UL 746 | PLC 0 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
RTI Elec | | UL 746 | 50.0 °C |
RTI | | UL 746 | 50.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.