Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D792 | 1.04 g/cm³ | |
ISO 1183 | 1.04 g/cm³ | ||
melt mass-flow rate | ASTM D1238 | 5.0 g/10min | |
Melt volume flow rate | ISO 1133 | 5.00 cm3/10min | |
Shrinkage rate | ASTM D955 | 0.20-0.60 % | |
ISO 294-4 | 0.20-0.60 % | ||
Water absorption rate | ASTM D570 | 0.10 % | |
ISO 62 | 0.10 % |
optical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
refractive index | ASTM D542 | 1.570 | |
ISO 489 | 1.570 | ||
transmissivity | ASTM D1003 | 90.0 % | |
Haze ratio | ASTM D1003 | 2.2 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | ASTM D638 | 20.7 Mpa | |
ISO 527-2 | 21.0 Mpa | ||
elongation | ASTM D638 | 50 % | |
Flexural modulus | ASTM D790 | 1550 Mpa | |
ISO 178 | 1650 Mpa | ||
bending strength | ASTM D790 | 37.2 Mpa | |
ISO 178 | 37.0 Mpa | ||
Rockwell hardness | ASTM D785 | 70 | |
Tensile modulus | ASTM D638 | 1520 Mpa | |
ISO 527-2 | 1520 Mpa |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
vicat | ASTM D15252 | 93.9 °C | |
maximum service temperature | 250 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.