PBT/PET SCHULADUR® PCR GF 15 BK

54

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
Melt volume flow rateISO113325.0 cm3/10min
hardnessTest ConditionTest MethodTest Result
ISO86880
ISO2039-1199 Mpa
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO527-2/1A/16000 Mpa
Tensile stressISO527-2/1A/585.0 Mpa
Tensile strainISO527-2/1A/52.0 %
Bending modulus 2ISO1787500 Mpa
Bending strength 2ISO178130 Mpa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of simply supported beam without notchISO179/1eU26 kJ/m²
Impact strength of simply supported beam without notchISO179/1eU22 kJ/m²
Thermal performanceTest ConditionTest MethodTest Result
ISO75-2/Af166 °C
vicatISO306/A120210 °C
vicatISO306/B50193 °C
ISO75-2/Bf207 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.