PP Tekucom SC GF 20 C TEKUMA Kunststoff GmbH
0
- Properties:Filler glass fiber reinforced material 20% filler by weight
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C,3.20mm | ASTM D256 | 110 J/m |
| 0°C,3.20mm | ASTM D256 | 90 J/m | |
| -30°C,3.20mm | ASTM D256 | 70 J/m |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot filament ignition temperature | IEC 60695-2-13 | 650 °C | |
| UL flame retardant rating | 3.2mm | UL 94 | HB |
| 1.6mm | UL 94 | HB |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| tensile strength | Yield | ASTM D638 | 75.0 MPa |
| bending strength | ASTM D790 | 110 MPa | |
| Bending modulus | ASTM D790 | 4500 MPa | |
| elongation | Break | ASTM D638 | 3.0 % |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| thermal conductivity | ASTMC177 | 0.25 W/m/K | |
| Vicat softening temperature | -- | ISO 306/B120 | 140 °C |
| -- | ASTM D15252 | 160 °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 145 °C |
| 0.45MPa,Unannealed | ASTM D648 | 157 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Water absorption rate | 23°C,24hr | ASTM D570 | 0.10 % |
| melt mass-flow rate | 250°C/2.16kg | ASTM D1238 | 4.0 g/10min |
| density | ASTM D792 | 1.04 g/cm³ |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Dissipation factor | IEC 60250 | 1.0E-3到1.5E-3 | |
| Dielectric constant | 1MHz | IEC 60250 | 2.30 |
| Dielectric strength | IEC 60243-1 | 40to80 kV/mm |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Rockwell hardness | R-Scale | ASTM D785 | 110 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.