PA6T ARLEN™  C240

247
  • Properties:
    Glass fiber reinforced
  • Usages:
    Electrical field
    Electronic field

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
Shrinkage rateASTM D-9550.4(0.8) %
Basic performanceTest ConditionTest MethodTest Result
Water absorption rateASTM D-5700.2(2.8) %
Mechanical propertiesTest ConditionTest MethodTest Result
Rockwell hardnessASTM D-785110 M Scale
Flexural modulusASTM D-79013000(9000) Mpa
bending strengthASTM D-790300(260) Mpa
Impact strength of cantilever beam gapASTM D-25685(90) J/m
elongationASTM D-6383(3) %
tensile strength ASTM D-638210(180) Mpa
Other performanceTest ConditionTest MethodTest Result
Glass Fiber Content40 %
Electrical performanceTest ConditionTest MethodTest Result
Dissipation FactorASTM D-1500.018
dielectric constantASTM D-1504.5
dielectric strengthASTM D-14930 KV/mm
Volume resistivityASTM D-25710 Ω.cm
Thermal performanceTest ConditionTest MethodTest Result
Glass transition temperature (Tg)85 °C
melting temperature310 °C
Heat distortion temperatureASTM D-648300 °C
UL flame retardant ratingUL 94HB
Linear coefficient of thermal expansionASTM D-6962.0(4.5)
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.