PC APEC 2097 COVESTRO GERMANY
60
Form:Granules | Grade:Injection grade
Properties:
UV curingGood demolding performancHigh temperature resistanHigh mobility
Typical Applications:
Automotive sectorCastersMedical suppliesNursing supplies
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive sector | Casters | Medical supplies | Nursing supplies |
| Properties: | UV curing | Good demolding performanc | High temperature resistan | High mobility |
Certificates
No Data...
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Refractive index | ISO 489 | 1.566 | ||
| transmissivity | 1000 μm | ISO 13468-2 | 89.0 | % |
| Electrolytic corrosion | 23°C | IEC 60426 | A1 | |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 无断裂 | |
| 23°C | ISO 179/1eU | 无断裂 | ||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.5 mm | UL 94 | HB | |
| Burning wire flammability index | IEC 60695-2-12 | 800 | °C | |
| Extreme Oxygen Index | ISO 4589-2 | 25 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 23°C | ISO 527-2/1 | 2450 | Mpa |
| tensile strength | Yield, 23°C | ISO 527-2/50 | 76.0 | Mpa |
| Tensile strain | Yield, 23°C | ISO 527-2/50 | 6.9 | % |
| Nominal tensile fracture strain | 23°C | ISO 527-2/50 | > 50 | % |
| Bending modulus | 23°C | ISO 178 | 2450 | Mpa |
| bending strength | 23°C | ISO 178 | 110 | Mpa |
| injection | Test Condition | Test Method | Test Result | Test Unit |
| Drying Temperature - Dry Air Dryer | 130 | °C | ||
| Drying time - Dry Air Dryer | 2.0 to 4.0 | hr | ||
| Suggested maximum moisture content | < 0.020 | % | ||
| Suggested injection volume | 30 to 70 | % | ||
| Temperature at the rear of the barrel | 315 to 325 | °C | ||
| Temperature in the middle of the barrel | 320 to 330 | °C | ||
| Temperature at the front of the material cylinder | 325 to 335 | °C | ||
| Spray nozzle temperature | 315 to 340 | °C | ||
| Processing (melt) temperature | 330 to 340 | °C | ||
| Mold temperature | 110 to 150 | °C | ||
| Back pressure | 10.0 to 20.0 | Mpa | ||
| Exhaust hole depth | 0.025 to 0.050 | mm | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 191 | °C |
| 1.8 MPa, Unannealed | ISO 75-2/A | 172 | °C | |
| Vicat softening temperature | ISO 306/B120 | 202 | °C | |
| Linear coefficient of thermal expansion | Flow : 23 to 55°C | ISO 11359-2 | 6.5E-5 | cm/cm/°C |
| Across Flow : 23 to 55°C | ISO 11359-2 | 6.5E-5 | cm/cm/°C | |
| RTI Elec | UL 746 | 150 | °C | |
| RTI Imp | UL 746 | 130 | °C | |
| RTI | UL 746 | 150 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | 23°C | ISO 1183 | 1.13 | g/cm³ |
| melt mass-flow rate | 330°C/2.16 kg | ISO 1133 | 8.0 | g/10 min |
| Melt Volume Flow Rate (MVR) | 330°C/2.16 kg | ISO 1133 | 8.00 | cm3/10min |
| Shrinkage rate | 横向Flow : 2.00 mm | ISO 294-4 | 0.90 | % |
| Flow : 2.00 mm | ISO 294-4 | 0.90 | % | |
| Water absorption rate | Saturation, 23°C | ISO 62 | 0.30 | % |
| Equilibrium, 23°C, 50% RH | ISO 62 | 0.12 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | 1.0E+16 | ohms | |
| Volume resistivity | 23°C | IEC 60093 | 1.0E+17 | ohms·cm |
| Dielectric strength | 23°C, 1.00 mm | IEC 60243-1 | 35 | KV/mm |
| Relative permittivity | 23°C, 100 Hz | IEC 60250 | 2.90 | |
| 23°C, 1 MHz | IEC 60250 | 2.80 | ||
| Dissipation factor | 23°C, 100 Hz | IEC 60250 | 1.0E-3 | |
| 23°C, 1 MHz | IEC 60250 | 9.0E-3 | ||
| Compared to the anti leakage trace index | Solution A | IEC 60112 | PLC 0 | |
| Solution B | IEC 60112 | PLC 4 | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | ISO 2039-1 | 130 | Mpa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.