PBT 4130-104K ZHANGZHOU CHANGCHUN
254
Form:Granules | Grade:Injection grade
Properties:
Glass fiber reinforcedFlame retardantHigh temperature resistan
Typical Applications:
Automotive sectorElectrical fieldElectronic fieldHome appliance components
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Automotive sector | Electrical field | Electronic field | Home appliance components |
| Properties: | Glass fiber reinforced | Flame retardant | High temperature resistan |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Simply supported beam without notch impact at 23 ℃ | ISO 179 | 50 | ||
| Charpy Notched Impact Strength | 23℃ | ISO 179 | 8.5 | kJ/m² |
| Bending modulus | ISO 178 | 8000 | Mpa | |
| bending strength | ISO 178 | 180 | Mpa | |
| Elongation at Break | ISO 527 | 2.5 | % | |
| ISO 527 | 125 | Mpa | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 11357 | 225 | °C | |
| Hot deformation temperature | Unannealed1.8MPa | ISO 75 | 200 | °C |
| Unannealed0.45MPa | ISO 75 | 215 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Network Fusion Index 260 ℃ 2.16kg | ISO 1133 | 12 | g/10min | |
| Shrinkage rate | Flow | ISO 294 | 0.8-1.2 | % |
| ISO 294 | 0.2-0.5 | % | ||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | 2.0mm | IEC 60243 | 20 | KC/mm |
| Volume resistivity | IEC 60093 | 10000000000000 | Ω | |
| IEC 60093 | 10000000000000 | Ω.cm | ||
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 3.0mm | UL 94 | V-0 5VA | |
| 1.5mm | UL 94 | V-0 5VA | ||
| 0.74mm | UL 94 | V-0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.