Properties:
Filler glass fiber reinforced material 30% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material | 30% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| tensile strength | 23°C | ISO 527-2 | 135 | MPa |
| Elongation at Break | 23°C | ISO 527-2 | 4.0 | % |
| Tensile modulus | 23°C | ISO 527-2 | 8300 | MPa |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 18 | kJ/m² |
| -30°C | ISO 179/1eA | 12 | kJ/m² | |
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 78 | kJ/m² |
| 23°C | ISO 179/1eU | 85 | kJ/m² | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | ISO 306/B50 | 205 | °C | |
| ISO 306/A50 | 220 | °C | ||
| Hot deformation temperature | 1.80MPaAnnealed | ISO 75-2/Af | 200 | °C |
| 0.45MPaUnannealed | ISO 75-2/Bf | 215 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | (23°C,24hr) | ISO 62 | 1.90 | % |
| density | ISO 1183 | 1.31 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 相对漏电起痕指数 | IEC 60112 | 550 | V |
| Surface resistivity | IEC 60093 | >1.0E+15 | Ω.cm | |
| Volume resistivity | IEC 60093 | >1.0E+13 | Ω.cm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | ISO 2039-1 | 200 | MPa | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL -94 | HB | 1.50mm | |
| UL -94 | HB | 3.00mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.