Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ASTM D955 | 0.2 % |
Shrinkage rate | | ASTM D955 | 0.4 % |
other | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTM D638 | -- Mpa |
tensile strength | | ASTM D527-2 | 193 Mpa |
elongation | | ASTM D638 | 1.5 % |
Flexural modulus | | ASTM D790 | 15500 Mpa |
bending strength | | ASTM D790 | 276 Mpa |
Charpy Notched Impact Strength | | ISO 179/1eA | 7.8 kJ/m² |
Charpy Notched Impact Strength | | ISO 179/1eU | 33.1 kJ/m² |
Impact strength of cantilever beam gap | | ASTM D256 | 107 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Dielectric loss | | ASTM D150 | 0.011 |
Volume resistivity | | ASTM D257 | 1E+15 ohm*cm |
dielectric strength | | ASTM D149 | 23 KV/mm |
dielectric constant | | ASTM D150 | 4.10 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
melting temperature | | ASTM D3418 | 310 °C |
Heat distortion temperature | | ASTM D648 | 277 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.