Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Water absorption rate | ASTM D570 | 0.56 % | |
melt mass-flow rate | ASTM D1238 | 16-25 g/10min |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
IZOD notch impact strength | ASTM D256 | 53.4 J/m | |
tensile strength | ASTM D638 | 88.9 Mpa | |
Tensile modulus | ASTM D638 | 2470 Mpa | |
Tensile fracture elongation rate | ASTM D638 | 25-75 % | |
bending strength | ASTM D790 | 114 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Surface Resistivity | ASTM D257 | 10 ohms | |
ASTM D257 | 10 ohm-cm | ||
Dielectric Strength | ASTM D149 | 16 KV/mm | |
dielectric constant | ASTM D150 | 3.2 | |
loss factor | ASTM D150 | 0.004 | |
arc resistance | ASTM D495 | 50 sec | |
ASTM D3638 | 150 V | ||
Oxygen Index | ASTM D2863 | 40 % |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D648 | 195 °C | |
Coefficient of expansion | ASTM D696 | 0.00058 cm/cm/℃ | |
Maximum continuous operating temperature | ASTM D794 | 180 °C | |
Glass Transition Temperature | DSC | 223 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.