PA6 C 246 V30

44
  • Properties:
    Filler: Glass fiber reinf
    30% filler by weight
  • Usages:
    Power/Other Tools
    sporting goods

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
Water absorption rateISO620.95 %
flammabilityTest ConditionTest MethodTest Result
FlameRatingUL94HB
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO527-2/1A8200 Mpa
Tensile stressISO527-2/1A140 Mpa
Tensile strainISO527-24.0 %
Flexural modulusISO1788000 Mpa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of simply supported beam without notchISO179/1eU85 kJ/m²
Impact strength of simply supported beam without notchISO179/1eU86 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC600931E+14 ohms
Volume resistivityIEC600931E+15 ohms·cm
dielectric strengthIEC60243-1-- KV/mm
Dissipation FactorIEC602500.021
Thermal performanceTest ConditionTest MethodTest Result
ISO75-2/Af200 °C
melting temperatureISO11357-3222 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.