Unspecified Tekucom SC GF 30 C TEKUMA Kunststoff GmbH

0
  • Properties:
    Filler
    glass fiber reinforced material
    30%
    filler by weight

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTM D7921.12 g/cm³
melt mass-flow rateASTM D12383.0 g/10min
Water absorption rateASTM D5700.10 %
hardnessTest ConditionTest MethodTest Result
Rockwell hardnessR-ScaleASTM D785112
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94HB
UL flame retardant ratingUL 94HB
Hot filament ignition temperatureIEC 60695-2-13650 °C
Mechanical propertiesTest ConditionTest MethodTest Result
Flexural modulusASTM D7906000 MPa
bending strengthASTM D790140 MPa
elongationBreakASTM D6383.0 %
tensile strength YieldASTM D63890.0 MPa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTM D25675 J/m
Impact strength of cantilever beam gapASTM D25695 J/m
Impact strength of cantilever beam gapASTM D256120 J/m
Electrical performanceTest ConditionTest MethodTest Result
dielectric strengthIEC 60243-140to80 kV/mm
Dissipation FactorIEC 602501.0E-3到1.5E-3
dielectric constantIEC 602502.30
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureASTM D648160 °C
Heat distortion temperatureASTM D648152 °C
vicatASTM D15252161 °C
vicatISO 306/B120140 °C
thermal conductivityASTMC1770.25 W/m/K
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App

Top