Share
Add to compare

PA6 BKV30 000000 ENVALIOR WUXI

61

Form:Granules | Grade:Injection grade

Properties:
Glass fiber reinforcedFiller: Glass fiber reinf30%Filler by weight
Product Description
Certificates(0)
Datasheet

Product Description

Properties:Glass fiber reinforced | Filler: Glass fiber reinf | 30% | Filler by weight

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch-30°CISO 179/1eU70kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU80kJ/m²
Suspended wall beam without notch impact strength-30°CISO 180/1U60kJ/m²
Suspended wall beam without notch impact strength23°CISO 180/1U75kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating0.8mmUL 94HB
UL flame retardant rating1.5mmUL 94HB
UL flame retardant rating1.6mmUL 94HB
UL flame retardant rating3.0mmUL 94HB
UL flame retardant rating3.2mmUL 94HB
Burning wire flammability index2.0mmIEC 60695-2-12600°C
Extreme Oxygen IndexISO 4589-222%
BurningBehavior>1.00mmISO 3795passed
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulus23°CASTM D6389200Mpa
Tensile modulus-5°CISO 527-2/19800Mpa
elongationBreak,23°CASTM D6383.0%
Tensile strainBreak,23°CISO 527-2/53.0%
Tensile creep modulus1hrISO 899-1--Mpa
Tensile creep modulus1000hrISO 899-1--Mpa
bending strength3.5%StrainISO 178/A--Mpa
bending strength23°CISO 178280Mpa
bending strengthFlexuralStrainatFlexuralStrength6(23°C)4.0%
bending strength23°CASTM D790280Mpa
Bending modulus23°CISO 178/A8600Mpa
Bending modulus23°CASTM D7908270Mpa
tensile strengthBreak,23°CISO 527-2/5180Mpa
tensile strengthBreak,23°CASTM D638180Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Vicat softening temperature--ISO 306/B50200°C
Vicat softening temperature--ISO 306/B120>200°C
Melting temperatureISO 11357-3222°C
Linear coefficient of thermal expansionMD:23to55°CISO 11359-22E-05cm/cm/°C
Linear coefficient of thermal expansionTD:23to55°CISO 11359-28E-05cm/cm/°C
RTI Elec1.5mmUL 746130°C
RTI Imp0.8mmUL 74695.0°C
RTI Imp1.5mmUL 74695.0°C
RTI Str0.8mmUL 746130°C
RTI Str1.5mmUL 746130°C
Hot deformation temperature0.45MPa,Unannealed,4.00mmASTM D648215°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A200°C
Hot deformation temperature1.8MPa,Unannealed,4.00mmASTM D648200°C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B215°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Apparent densityISO 600.70g/cm³
Melt Volume Flow Rate (MVR)260°C/5.0kgISO 113314.0cm3/10min
Shrinkage rateTD:280°C,3.00mm2ISO 25770.82%
Shrinkage rateTD:120°C,2hr,3.00mm3ISO 294-40.12%
Shrinkage rateMD:280°C,3.00mm2ISO 25770.16%
Water absorption rateEquilibrium,23°C,50%RHISO 622.1%
Water absorption rateSaturation,23°CISO 627.0%
Shrinkage rateMD:120°C,2hr,3.00mm3ISO 25770.030%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Relative permittivity23°C,1MHzIEC 602504.00
Dissipation factor23°C,50HzIEC 602505E-03
Dissipation factor23°C,100HzIEC 602505E-03
Dissipation factor23°C,1MHzIEC 602500.0150.015
Arc resistanceASTM D495--sec
Surface resistivityIEC 600931E+14ohms
Volume resistivity23°CIEC 600931E+15ohms·cm
Dielectric strength23°C,1.00mmIEC 60243-140KV/mm
Dielectric strength23°C,3.00mmIEC 60243-140KV/mm
Dielectric constant23°C,50HzIEC 602504.00
Dielectric constant23°C,1MHzIEC 602504.00
Relative permittivity23°C,100HzIEC 602504.00
hardnessTest ConditionTest MethodTest ResultTest Unit
Ball Pressure TestISO 2039-1210Mpa
filmTest ConditionTest MethodTest ResultTest Unit
Thin film puncture strength--7ISO 6603-28.00J
Thin film puncture strength--8ISO 6603-26.00J
Thin film puncture strength--8ISO 6603-2950N
Thin film puncture strength--7ISO 6603-21070N
Supplementary InformationTest ConditionTest MethodTest ResultTest Unit
ISO ShortcutISO 1874PA6.GR.14-100.GF30
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.