PP 5090R FPC TAIWAN
350
Form:Granules | Grade:Medical grade
Properties:
Chemical resistanceHigh transparency
Typical Applications:
Medical suppliesNursing supplies
Product Description
Certificates(1)
Datasheet
Alternative(1)
Product Description
| Typical Applications: | Medical supplies | Nursing supplies |
| Properties: | Chemical resistance | High transparency |
Certificates
TDS
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23℃23℃ | ISO 180 | 9 | kg.cm/cm |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | ISO 178 | 931.95 | Mpa | |
| Rockwell hardness | ISO 2039 | 98 | R 级 | |
| Tensile strain | Break | ISO 527 | 300 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | HDT | ISO 75 | 95 | °C |
| Vicat softening temperature | ISO 306 | 125 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | FPC Method | 1.3-1.7 | % | |
| Tensile stress | Yield | ISO 527 | 280 | Kg/cm 2 |
| Melting temperature | DSC | 146 | °C | |
| density | ISO 1183 | 0.9 | g/cm³ | |
| melt mass-flow rate | ISO 1133 | 15 | g/10min |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.