PPA DENYL HT 6010 VAMP TECH ITALY
Properties:
Filler glass fiber reinforced material 60% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material | 60% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ISO 180/A | 10 | kJ/m² | |
| Suspended wall beam without notch impact strength | ISO 180 | 50 | kJ/m² | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ASTM D638 | 23000 | MPa | |
| tensile strength | Yield | ASTM D638 | 250 | MPa |
| elongation | Break | ASTM D638 | 1.6 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648A | 280 | °C |
| RTI Elec | UL 746 | 150 | °C | |
| RTI Imp | UL 746 | 150 | °C | |
| RTI | UL 746 | 150 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 1.73 | g/cm³ | |
| Shrinkage rate | MD | ASTM D955 | 0.050 | % |
| TD | ASTM D955 | 0.30 | % | |
| Water absorption rate | Saturation | ASTM D570 | 0.30 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 | ||
| Surface resistivity | ASTM D257 | 1E+12 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.