Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792 | 1.51 g/cm³ |
Shrinkage rate | | ASTMD955 | 0.30 % |
Shrinkage rate | | ASTMD955 | 0.40 % |
Water absorption rate | | ASTMD570 | 0.36 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | R-Scale | ASTMD785 | 134 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | V-0 |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Suspended wall beam without notch impact strength | | ASTMD256 | 430 J/m |
Impact strength of cantilever beam gap | | ASTMD256 | 80 J/m |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ASTMD638 | 124 MPa |
elongation | Break | ASTMD638 | 3.0 % |
Flexural modulus | | ASTMD790 | 5900 MPa |
bending strength | | ASTMD790 | 172 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
arc resistance | | ASTMD495 | 150 sec |
Volume resistivity | | ASTMD257 | 1E+16 ohms·cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat Deflection Temperature | | ASTMD648 | 210 °C |
Linear thermal expansion coefficient | | ASTMD696 | 2.6E-05 cm/cm/°C |
Linear thermal expansion coefficient | | ASTMD696 | 4.8E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.