Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792 | 1.30 g/cm³ |
melt mass-flow rate | | ASTMD1238 | 7.0 g/10min |
Water absorption rate | | ASTMD570 | 0.20 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | M-Scale | ASTMD785 | 92 |
flammability | Test Condition | Test Method | Test Result |
---|
Limiting Oxygen Index | | ASTMD2863 | 38 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile stress | Yield | ISO527-2/1A/50 | 89.0 MPa |
Tensile stress | | ASTMD638 | 92.0 MPa |
elongation | | ASTMD638 | 6.0 % |
elongation | Yield | ISO527-2/1A/50 | 5.4 % |
elongation | | ASTMD638 | 50到80 % |
elongation | Break | ISO527-2/1A/50 | 50到80 % |
Flexural modulus | | ASTMD790 | 320 MPa |
Flexural modulus | | ISO178 | 3300 MPa |
bending strength | | ASTMD790 | 127 MPa |
bending strength | | ISO178 | 128 MPa |
shear strength | | ASTMD732 | 79.0 MPa |
compressive strength | | ASTMD695 | 110 MPa |
Tensile modulus | | ASTMD638 | 3300 MPa |
Tensile modulus | | ISO527-2/1A/1 | 3400 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTMD256 | 91 J/m |
Impact strength of cantilever beam gap | | ISO180 | 7.0 kJ/m² |
Suspended wall beam without notch impact strength | | ASTMD4812,ISO180 | 无断裂 |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | ASTMD257 | >1.9E+17 ohms |
Volume resistivity | | ASTMD257 | 6.2E+17 ohms·cm |
dielectric strength | | ASTMD149 | 180 kV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTMD648 | 181 °C |
Glass Transition Temperature | | ASTMD3418 | 158 °C |
| | ASTMD3418 | 340 °C |
specific heat | | DSC | 1390 J/kg/°C |
specific heat | | DSC | 1960 J/kg/°C |
thermal conductivity | | ASTME1530 | 0.23 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.