Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.04 g/cm³ |
density | | ISO 1183 | 1.04 g/cm³ |
melt mass-flow rate | | ASTM D1238 | 2.3 g/10min |
melt mass-flow rate | | ISO 1133 | 2.3 g/10min |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | HB |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
Residual Monomer | | | <700 ppm |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
bending strength | | ASTM D790 | 98.1 Mpa |
bending strength | | ISO 178 | 98.0 Mpa |
tensile strength | | ASTM D638 | 51.0 Mpa |
tensile strength | | ISO 527-2 | 51.0 Mpa |
elongation | | ASTM D638 | 2.0 % |
Tensile strain | | ISO 527-2 | 2.0 % |
Flexural modulus | | ASTM D790 | 3330 Mpa |
Flexural modulus | | ISO 178 | 3330 Mpa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ISO 180 | 18 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 18 J/m |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D648 | 95.0 °C |
Heat distortion temperature | | ISO 75-2/A | 95.0 °C |
vicat | | ASTM D1525 | 104 °C |
vicat | | ISO 306/B | 104 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.