PPS FZ-928N DIC JAPAN
29
Form:Granules | Grade:Injection grade
Properties:
Filler: Glass fiber reinf
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler: Glass fiber reinf |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Suspended wall beam without notch impact strength | ASTM D256 | 650 | J/m | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ASTM D638 | 7500 | Mpa | |
| tensile strength | ASTM D638 | 135 | Mpa | |
| elongation | Break | ASTM D638 | 2.1 | % |
| Bending modulus | ASTM D790 | 6600 | Mpa | |
| bending strength | ASTM D790 | 180 | Mpa | |
| compressive strength | ASTM D695 | 170 | Mpa | |
| Poisson's ratio | 7.58 | 0.37 | ||
| Friction coefficient | Steel - Dynamic | ASTM D1894 | 0.35 | |
| Steel - Static | ASTM D1894 | 0.35 | ||
| Elongation at Break | ASTM D790 | 3.4 | % | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | 230 | °C |
| Linear coefficient of thermal expansion | MD:-30to100°C | ASTM D696 | 3.5E-05 | cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD | ASTM D955 | 0.32 | % |
| TD | ASTM D955 | 1.2 | % | |
| Water absorption rate | 23°C,24hr | ASTM D570 | 0.020 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ASTM D257 | 1E+16 | ohms·cm | |
| Dielectric strength | 1.60mm | ASTM D149 | 24 | KV/mm |
| Dielectric constant | 1MHz | ASTM D150 | 4.00 | |
| Dissipation factor | 1MHz | ASTM D150 | 2E-03 | |
| Arc resistance | ASTM D495 | 120 | sec | |
| Compared to the anti leakage trace index | ASTM D3638 | V | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | M-Scale | ASTM D785 | 84 | |
| R-Scale | ASTM D785 | 118 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.