PBT GERMADUR HSZ Kunststoff-Kontor-Hamburg GmbH
0
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of simply supported beam without notch | ISO 179 | 无断裂 | |
| Charpy Notched Impact Strength | ISO 179 | 45 kJ/m² |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | UL 94 | HB |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile strain | Break | ISO 527-2 | 20 % |
| tensile strength | Yield | ISO 527-2 | 50.0 MPa |
| Tensile modulus | ISO 527-2 | 1900 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Melting temperature | 225 °C | ||
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 140 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| density | ISO 1183 | 1.20 g/cm³ | |
| Melt Volume Flow Rate (MVR) | 250°C/2.16kg | ISO 1133 | 45.0 cm³/10min |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Surface resistivity | IEC 60093 | 1E+13 ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.