PC NEMCON H PC DP120/X2

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTMD7921.60 g/cm³
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusASTMD6383100 MPa
tensile strengthBreakASTMD63845.0 MPa
Flexural modulusASTMD7906000 MPa
bending strengthASTMD79075.0 MPa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTMD25627 J/m
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityASTMD2578E+12 ohms
Thermal performanceTest ConditionTest MethodTest Result
ASTMD648130 °C
thermal conductivityASTME14612.2 W/m/K
thermal conductivityASTME14616.2 W/m/K
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.