Share
Add to Compare

PA612 SCHULAMID® 612 FS 4003 A SCHULMAN USA

Product Description
Certificates(0)
Datasheet

Product Description

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Charpy Notched Impact Strength-30°CISO 179/1eA30kJ/m²
Charpy Notched Impact Strength23°CISO 179/1eA98kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eUNoBreak
Impact strength of simply supported beam without notch23°CISO 179/1eUNoBreak
flammabilityTest ConditionTest MethodTest ResultTest Unit
Hot filament ignition temperature3.0mmIEC 60695-2-13750°C
Burning rateISO 3795<20mm/min
UL flame retardant rating1.5mmIEC 60695-11-10,-20HB
UL flame retardant rating3.0mmIEC 60695-11-10,-20HB
Burning wire flammability index1.5mmIEC 60695-2-12725°C
Burning wire flammability index3.0mmIEC 60695-2-12725°C
Hot filament ignition temperature1.5mmIEC 60695-2-13750°C
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulusISO 527-2/1A/11750MPa
tensile strengthYieldISO 527-2/1A/5046.0MPa
Tensile strainYieldISO 527-2/1A/505.0%
Nominal tensile fracture strainISO 527-2/1A/50>100%
Bending modulusISO 1781250MPa
bending strengthISO 17852.0MPa
Bending strainISO 1788.00MPa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.8MPa,UnannealedISO 75-2/Af60.0°C
Vicat softening temperature--ISO 306/A50200°C
Vicat softening temperature--ISO 306/B50140°C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/Bf145°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityISO 1183/A1.04g/cm³
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.