ABS VAMPALLOY 0024 V0 13 VAMP TECH ITALY
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ISO 180/A | 35 | kJ/m² | |
| Suspended wall beam without notch impact strength | ISO 180 | 无断裂 | ||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | V-0 | |
| 3.2mm | UL 94 | V-0 | ||
| Burning wire flammability index | 1.0to2.0mm | IEC 60695-2-12 | 960 | °C |
| Hot filament ignition temperature | 1.0to2.0mm | IEC 60695-2-13 | 775 | °C |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ASTM D638 | 2500 | MPa | |
| tensile strength | Yield | ASTM D638 | 50.0 | MPa |
| elongation | Break | ASTM D638 | >50 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | ASTM D15253 | 130 | °C | |
| RTI Elec | UL 746 | 100 | °C | |
| RTI Imp | UL 746 | 100 | °C | |
| RTI | UL 746 | 100 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648A | 110 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 1.19 | g/cm³ | |
| Shrinkage rate | MD | ASTM D955 | 0.60 | % |
| TD | ASTM D955 | 0.60 | % | |
| Water absorption rate | Saturation | ASTM D570 | 0.15 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 2 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.