Epoxy EPO-TEK® E3037 Epoxy Technology Inc.
Properties:
Filler silver
Typical Applications:
Electrical and electronic applications adhesives
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical and electronic applications | adhesives |
| Properties: | Filler | silver |
Certificates
No Data...
Technical Data Sheet
| Cured Properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Shore hardness | ShoreD | 80 | ||
| LapShearStrength | 23°C | 13.0 | MPa | |
| Volume resistivity | 23°C | <5.0E-4 | ohms·cm | |
| Uncured Properties | Test Condition | Test Method | Test Result | Test Unit |
| viscosity | 23°C | 22to26 | Pa·s | |
| Curing time | 150°C | 1.0 | hr | |
| storage stability | 40000 | min | ||
| Color | Silver | |||
| density | 3.06 | g/cm³ | ||
| thermosetting | Test Condition | Test Method | Test Result | Test Unit |
| shelf-life | -40°C | 52 | wk | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Glass transition temperature | >90.0 | °C | ||
| Linear coefficient of thermal expansion | MD:--2 | 5.2E-05 | cm/cm/°C | |
| MD:--3 | 1.5E-04 | cm/cm/°C | ||
| MD:导热系数 | 1.6 | W/m/K | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Ionic type | Cl- | 187 | ppm | |
| K+ | 3 | ppm | ||
| Na+ | 22 | ppm | ||
| NH4+ | 65 | ppm | ||
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| weight loss on heating | 250°C | 0.41 | % | |
| 300°C | 0.80 | % | ||
| DegradationTemperature | 358 | °C | ||
| Shear Strength | 23°C | 23.4 | MPa | |
| operate temperature | Continuous | -55-200 | °C | |
| Intermittent | -55-300 | °C | ||
| StorageModulus(23°C) | 5.02 | GPa | ||
| ThixotropicIndex | 3.62 | |||
| weight loss on heating | 200°C | 0.13 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.