0
  • Usages:
    Electrical components
  • Compare

Technical Data Sheet

impact performanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTM D256160 J/m
flammabilityTest ConditionTest MethodTest Result
UL flame retardant rating1.6mmUL 94HB
mechanical propertiesTest ConditionTest MethodTest Result
compressive strengthASTM D695145 MPa
bending strengthYieldASTM D79089.6 MPa
tensile strengthYieldASTM D63834.5 MPa
Bending modulusASTM D79013100 MPa
thermal performanceTest ConditionTest MethodTest Result
Hot deformation temperature1.8MPa,UnannealedASTM D648260 °C
Physical propertiesTest ConditionTest MethodTest Result
Water absorption rate24hrASTM D5700.070 %
Shrinkage rateMDASTM D9550.10to0.40 %
densityASTM D7921.94 g/cm³
Electrical performanceTest ConditionTest MethodTest Result
Arc resistance1.59mmASTM D495180 sec
Dielectric strengthASTM D14917 kV/mm
Volume resistivityASTM D2572.8E+16 ohms·cm
Compared to the anti leakage trace index1.59mmUL 746PLC 1
hardnessTest ConditionTest MethodTest Result
Babbitt hardnessASTM D258340
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.