SPS XAREC™ S932 IDEMITSU JAPAN
38
- Properties:High temperature resistanGlass fiber reinforced
- Usages:Household daily necessitiesElectrical applications
- Certificates:UL
Technical Data Sheet
| other | Test Condition | Test Method | Test Result |
|---|---|---|---|
| purpose | 薄膜按键开关.电器用具.汽车领域的应用等。 |
| Basic Performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Water absorption rate | 24hr | ASTM D-570 | 0.070 % |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| elongation at yield | ASTM D-638 | 2.1 % | |
| Bending modulus | ASTM D-790 | 9500 Mpa | |
| bending strength | ASTM D-790 | 165 Mpa | |
| Rockwell hardness | ASTM D-785 | 75 M-scale | |
| tensile strength | Yield | ASTM D-638 | 105 Mpa |
| Rockwell hardness | ASTM D785 | 75 | |
| bending strength | ASTM D790/ISO 178 | 23900 psi kg/cm²(MPa)[Lb/in²] |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 0.45MPa,Unannealed | ASTM D-648 | 265 °C |
| 1.80MPa,Unannealed | ASTM D-648 | 245 °C | |
| Linear coefficient of thermal expansion | Flow | ASTM D-696 | 0.000025 cm/cm/℃ |
| UL flame retardant rating | 0.0312mm | UL 94 | V-0 |
| Combustibility (rate) | UL 94 | V-0 |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | Flow | ASTM D-955 | 0.30 % |
| density | ASTM D792/ISO 1183 | 1.44 | |
| Water absorption rate | ASTM D570/ISO 62 | 0.07 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Volume resistivity | ASTM D-257 | 1E+16 ohm.cm | |
| Dielectric strength | ASTM D-149 | 35.0 KV/mm | |
| Dielectric constant | 1E+6Hz | ASTM D-150 | 3.000 |
| Dielectric loss | 1E+6Hz | ASTM D-150 | 0.0020 |
| Volume resistivity | ASTM D257/IEC 60093 | 1.0E+16 Ω.cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.