PEI HU1000-1H1000 SABIC INNOVATIVE US
110
Form:Granules
Properties:
Middle flowBiocompatibilitySteam sterilization
Typical Applications:
Medical devicesMedical and nursing supplies
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Medical devices | Medical and nursing supplies |
| Properties: | Middle flow | Biocompatibility | Steam sterilization |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Suspended wall beam without notch impact strength | 23°C | ASTM D4812 | 1300 | J/m |
| Dart impact | 23°C, Total Energy | ASTM D3763 | 0.00 | J |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Extreme Oxygen Index | ASTM D2863 | 47 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | --2 | ASTM D638 | 3580 | Mpa |
| -- | ISO 527-2/1 | 3200 | Mpa | |
| tensile strength | Yield3 | ASTM D638 | 110 | Mpa |
| Yield | ISO 527-2/5 | 105 | Mpa | |
| Break3 | ASTM D638 | 90.0 | Mpa | |
| Break | ISO 527-2/5 | 85.0 | Mpa | |
| elongation | Yield3 | ASTM D638 | 7.0 | % |
| Yield | ISO 527-2/5 | 6.0 | % | |
| Break3 | ASTM D638 | 60 | % | |
| Break | ISO 527-2/5 | 60 | % | |
| Bending modulus | 50.0 mm Span4 | ASTM D790 | 3430 | Mpa |
| --5 | ISO 178 | 3300 | Mpa | |
| bending strength | --5,6 | ISO 178 | 160 | Mpa |
| Yield, 50.0 mm Span4 | ASTM D790 | 173 | Mpa | |
| injection | Test Condition | Test Method | Test Result | Test Unit |
| Temperature at the front of the material cylinder | 345 to 400 | °C | ||
| Temperature in the middle of the barrel | 340 to 400 | °C | ||
| Temperature at the rear of the barrel | 330 to 400 | °C | ||
| Suggested injection volume | 40 to 60 | % | ||
| Suggested maximum moisture content | 0.020 | % | ||
| drying time | 4.0 to 6.0 | hr | ||
| drying temperature | 150 | °C | ||
| Spray nozzle temperature | 345 to 400 | °C | ||
| Processing (melt) temperature | 350 to 400 | °C | ||
| Mold temperature | 135 to 165 | °C | ||
| Back pressure | 0.300 to 0.700 | Mpa | ||
| Screw speed | 40 to 70 | rpm | ||
| Exhaust hole depth | 0.025 to 0.076 | mm | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8 MPa, Unannealed, 6.40 mm | ASTM D648 | 201 | °C |
| 1.8 MPa, Unannealed, 4.00 mm, 64.0 mm Span8 | ISO 75-2/Af | 215 | °C | |
| Vicat softening temperature | -- | ASTM D15259 | 218 | °C |
| Linear coefficient of thermal expansion | Across Flow : -40°C | ISO 11359-2 | 5.0E-5 | cm/cm/°C |
| Across Flow : -20 to 150°C | ASTM E831 | 5.4E-5 | cm/cm/°C | |
| Flow : -40 to 40°C | ISO 11359-2 | 5.0E-5 | cm/cm/°C | |
| Flow : -20 to 150°C | ASTM E831 | 5.6E-5 | cm/cm/°C | |
| Vicat softening temperature | -- | ISO 306/B120 | 211 | °C |
| -- | ISO 306/B50 | 215 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 337°C/6.6 kg | ASTM D1238 | 9.0 | g/10 min |
| Melt Volume Flow Rate (MVR) | 220°C/5.0 kg | ISO 1133 | 13.0 | cm3/10min |
| Shrinkage rate | 3.20 mm,Flow | Internal Method | 0.50 - 0.70 | % |
| Water absorption rate | 24 hr | ASTM D570 | 0.25 | % |
| Saturation, 23°C | ISO 62 | 1.3 | % | |
| Equilibrium, 23°C | ASTM D570 | 1.3 | % | |
| Equilibrium, 23°C, 50% RH | ISO 62 | 0.70 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot wire ignition | UL 746 | PLC 1 | ||
| High voltage arc tracing rate | UL 746 | PLC 2 | ||
| High arc combustion index | UL 746 | PLC 3 | ||
| Compared to the anti leakage trace index | UL 746 | PLC 4 | ||
| Arc resistance | ASTM D495 | PLC 5 | ||
| Dissipation factor | 2.45 GHz | ASTM D150 | 2.5E-3 | |
| 1 kHz | ASTM D150 | 1.3E-3 | ||
| Dielectric constant | 1 kHz | ASTM D150 | 3.15 | |
| Dielectric strength | 1.60 mm, in Oil | ASTM D149 | 28 | KV/mm |
| 1.60 mm, in Air | ASTM D149 | 33 | KV/mm | |
| Volume resistivity | ASTM D257 | 1.0E+17 | ohms·cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.