Technical Data Sheet
Basic performance | Test Condition | Test Method | Test Result |
---|---|---|---|
melt mass-flow rate | ASTM D-1238 | 0.85 g/10min | |
density | ASTM D-792 | 0.956 g/cm³ | |
Water absorption rate | ASTM D-570 | >0.01 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Rockwell hardness | ASTM D-785 | 47 scRale | |
Flexural modulus | ASTM D-790 | 9.000 Kgf/cm2 | |
Shrinkage rate | KPIC Method | 1.5-2.5 % | |
tensile strength | ASTM D-638 | 250 Kgf/cm2 | |
elongation at break | ASTM D-638 | <500 % | |
Impact strength of cantilever beam gap | ASTM D-256 | <50 Kgf.cm/cm |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
dielectric constant | ASTM D-150 | 2.3 | |
Volume resistivity | ASTM D-257 | 1 1017ohm.cm | |
dielectric strength | ASTM D-149 | 48 KV/mm | |
Dissipation Factor | ASTM D-150 | 2 10-4 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Linear coefficient of thermal expansion | ASTM D-696 | 1.5 10-5cm/cm°C | |
Variable temperature | ASTM D-746 | >-70 °C | |
specific heat | KPIC Method | 0.45 cal/g℃ | |
vicat | ASTM D-1525 | 123 °C | |
Heat distortion temperature | ASTM D-648 | 69 °C | |
melting temperature | ASTM D-3418 | 134 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Contact Us
Get App
Top