Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792 | 1.49 g/cm³ |
Shrinkage rate | | | 0.50到0.70 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | ASTMD785 | 107 |
flammability | Test Condition | Test Method | Test Result |
---|
exothermic | | FAR25.853 | <65 kW·min/m² |
exothermic | | FAR25.853 | <65 kW/m² |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
Ds | | ASTMF814 | <100 |
Ds | | ASTMF814 | <200 |
Ds | | ASTMF814 | 168到188 °C |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
bending strength | | ASTMD790 | 60.0 MPa |
tensile strength | | ASTMD638 | 37.9 MPa |
Flexural modulus | | ASTMD790 | 2830 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Suspended wall beam without notch impact strength | | ASTMD256 | 270 J/m |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTMD648 | 76.7 °C |
| | ASTMD696 | 3E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.