PP 7633-3 LCY TAIWAN
58
Form:Granules | Grade:Injection grade
Properties:
High impact resistanceAging resistanceheat-resistingLow temperature resistanc
Typical Applications:
Pipeline componentsAutomotive sectorPlastic boxPlastic bottlePipeline systemApplication in the automotive fieldLoading boxsheetbottlefurniture
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Pipeline components | Automotive sector | Plastic box | Plastic bottle | Pipeline system | Application in the automotive field | Loading box | sheet | bottle | furniture |
| Properties: | High impact resistance | Aging resistance | heat-resisting | Low temperature resistanc |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ASTM D256 | 160 | J/m |
| Suspended wall beam without notch impact strength | -18°C | ASTM D256 | 1300 | J/m |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Yield | ASTM D638 | 25.5 | Mpa |
| elongation | Yield | ASTM D638 | 7.0 | % |
| Bending modulus | ASTM D790 | 1300 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | HDT | ASTM D648 | 90 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 0.896 | g/cm³ | |
| melt mass-flow rate | 230°C/2.16kg | ASTM D1238 | 3.0 | g/10min |
| Shrinkage rate | MD | ASTM D955 | 1.4 | % |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ASTM D785 | 79 | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| Dart impact | -29°C | Internal Method | 32.5 | J |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.