Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Antistatic | Random copolymer |
Certificates
No Data...
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| turbidity | 2000μm | ISO 14782 | 30 | % |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of simply supported beam without notch | 23°C | ISO 179 | 6.0 | kJ/m² |
| Fracture rate | Test Condition | Test Method | Test Result | Test Unit |
| optical performance | 混浊 | ISO 14782 | 30 | % |
| Thermal Properties | 热变形温度,0.45MPa,Unannealed | ISO 75-2/B | 78 | °C |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ISO 178 | 29.0 | Mpa | |
| Elongation at Break | 洛氏硬度 | ISO 2039-2 | 76 | |
| 简支梁Notched冲击强度,23℃ | ISO 179 | 6.0 | kJ/m² | |
| ISO 527-2 | 200 | % | ||
| bending strength | ISO 178 | 29 | Mpa | |
| Bending modulus | ISO 178 | 950 | Mpa | |
| Tensile strain | Break | ISO 527-2 | 17 | % |
| Tensile stress | Yield | ISO 527-2 | 27 | Mpa |
| Tensile modulus | ISO 527-2 | 950 | Mpa | |
| Bending modulus | ISO 178 | 950 | Mpa | |
| Nominal tensile fracture strain | ISO 527-2 | 200 | % | |
| Tensile strain | Break | ISO 527-2 | 17 | % |
| tensile strength | Yield | ISO 527-2 | 27.0 | Mpa |
| Tensile modulus | ISO 527-2 | 950 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 78.0 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | Internal Method | 1.4-1.8 | % | |
| melt mass-flow rate | 230°C/2.16kg | ISO 1133 | 22 | g/10min |
| Shrinkage rate | Internal Method | 1.4-1.8 | % | |
| melt mass-flow rate | 230℃,2.16kg | ISO 1133 | 22 | g/10min |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Sale | ISO 2039-2 | 76 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.