
PA66 TAROMID A 280 G5 Taro Plast S.p.A.
Properties:
Filler glass fiber reinforced material 25% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material | 25% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ASTMD256 | 6.0 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ASTMD256 | 36 | kJ/m² |
| Impact strength of cantilever beam gap | 23°C,3.20mm | ISO 180 | 70 | J/m |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.750mm | UL 94 | HB | |
| Hot filament ignition temperature | 2.00mm | IEC 60695-2-13 | 750 | °C |
| Extreme Oxygen Index | ASTM D2863 | 26 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| elongation | Break | ASTMD638 | 3.0 | % |
| Bending modulus | ASTMD790 | 8500 | MPa | |
| crack | ASTM D790 | 230 | MPa | |
| Tensile modulus | ASTMD638 | 8800 | MPa | |
| tensile strength | Break | ASTMD638 | 146 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Continuous use temperature | --4 | IEC 60216 | 130 | °C |
| --5 | IEC 60216 | 140 | °C | |
| Linear coefficient of thermal expansion | MD:-30to30°C | ASTM D696 | 3.5E-05 | cm/cm/°C |
| Continuous use temperature | --6 | IEC 60216 | 180 | °C |
| Vicat softening temperature | ISO 306/B50 | 250 | °C | |
| Ball Pressure Test | 165°C | VDE0470 | Pass | |
| Melting temperature | ASTMD211 | 256 | °C | |
| Continuous use temperature | --3 | IEC 60216 | 100 | °C |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTMD648 | 238 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTMD792 | 1.30to1.32 | g/cm³ | |
| melt mass-flow rate | 280°C/2.16kg | ASTMD1238 | 15 | g/10min |
| Shrinkage rate | MD | ASTM D955 | 0.40to0.50 | % |
| TD | ASTM D955 | 1.0to1.4 | % | |
| saturated | ASTM D570 | 5.5 | % | |
| ISO 62 | 5.5 | % | ||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ASTM D257 | 8E+15 | ohms·cm | |
| Dielectric strength | 2.00mm | ASTM D149 | 24 | kV/mm |
| Compared to the anti leakage trace index | SolutionA | IEC 60112 | PLC 1 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ASTM D785 | 120 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.