Share
Add to Compare

PA66 FR52G30NHF NC010 DUPONT USA

39

Form:Granules | Grade:Injection grade

Properties:
High temperature resistanFlame retardantThermal stabilityGlass fiber reinforced
Typical Applications:
Automotive sectorElectrical appliancesElectronic fieldElectrical field
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Automotive sector | Electrical appliances | Electronic field | Electrical field
Properties:High temperature resistan | Flame retardant | Thermal stability | Glass fiber reinforced

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch23°CkJ/m²45
Impact strength of simply supported beam without notch-30°CkJ/m²40
flammabilityTest ConditionTest MethodTest ResultTest Unit
Burning wire flammability index0.400mm°C960--
Flammability level1.50mmV-0--
Flammability level0.400mmV-0--
Extreme Oxygen Index%37--
Hot filament ignition temperature3.00mm°C775--
Hot filament ignition temperature0.400mm°C700--
Burning wire flammability index3.00mm°C960--
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
bending strength225MPa
Bending modulusMPa980010800
Tensile strainBreak%2.11.9
tensile strengthBreak145MPa
Tensile modulusMPa1070011300
thermal performanceTest ConditionTest MethodTest ResultTest Unit
RTI Elec3.00mm°C140--
RTI Elec1.50mm°C140--
RTI Elec0.750mm°C140--
RTI Elec0.400mm°C140--
Linear coefficient of thermal expansionMD:-40to23°Ccm/cm/°C1.8E-05--
Linear coefficient of thermal expansionMDcm/cm/°C1.8E-05--
Melting temperature°C310--
Hot deformation temperature1.8MPa,Unannealed°C281--
Linear coefficient of thermal expansionMD:55to160°Ccm/cm/°C1.2E-05--
Linear coefficient of thermal expansionTDcm/cm/°C6.2E-05--
Linear coefficient of thermal expansionTD:-40to23°Ccm/cm/°C6E-05--
Linear coefficient of thermal expansionTD:55to160°Ccm/cm/°C9.5E-05--
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rateMD%0.30--
Shrinkage rateTD%1.0--
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Compared to the anti leakage trace indexVPLC 0
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.