PSU E2010G6 BASF GERMANY
137
Form:Granules
Properties:
High temperature resistanwear resistant
Typical Applications:
Food containersMedical equipment
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Food containers | Medical equipment |
| Properties: | High temperature resistan | wear resistant |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ISO 180 | 7.0 | kJ/m² |
| -30°C | ISO 180 | 7.5 | kJ/m² | |
| Impact strength of simply supported beam without notch | 23°C | ISO 179 | NoBreak | |
| -30°C | ISO 179 | NoBreak | ||
| Charpy Notched Impact Strength | 23°C | ISO 179 | 7.0 | kJ/m² |
| -30°C | ISO 179 | 7.5 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 3.0mm | UL 94 | V-0 | |
| 1.6mm | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | 23°C | ISO 527-2 | 2650 | Mpa |
| tensile strength | Yield,23°C | ISO 527-2 | 85.0 | Mpa |
| Tensile strain | Yield,23°C | ISO 527-2 | 6.9 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI Elec | 3.0mm | UL 746 | 180 | °C |
| 1.6mm | UL 746 | 180 | °C | |
| Linear coefficient of thermal expansion | MD | 5.2E-05 | cm/cm/°C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 205 | °C |
| RTI Str | 3.0mm | UL 746 | 190 | °C |
| 1.6mm | UL 746 | 190 | °C | |
| RTI Imp | 3.0mm | UL 746 | 180 | °C |
| 1.6mm | UL 746 | 180 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.37 | g/cm³ | |
| Melt Volume Flow Rate (MVR) | 360°C/10.0kg | ISO 1133 | 70.0 | cm3/10min |
| Shrinkage rate | TD | ISO 294-4 | 0.86 | % |
| MD | ISO 294-4 | 0.82 | % | |
| Water absorption rate | Saturation,23°C | ISO 62 | 2.2 | % |
| Equilibrium,23°C,50%RH | ISO 62 | 0.80 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 4 | ||
| Dissipation factor | 1MHz | IEC 60250 | 0.014 | |
| 100Hz | IEC 60250 | 1.7E-03 | ||
| Dielectric constant | 1MHz | IEC 60250 | 3.80 | |
| 100Hz | IEC 60250 | 3.90 | ||
| Dielectric strength | IEC 60243-1 | 37 | KV/mm | |
| Volume resistivity | IEC 60093 | >1.0E+13 | ohms·cm | |
| Surface resistivity | IEC 60093 | >1.0E+15 | ohms | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | ISO 2039-1 | 154 | Mpa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.