Share
Add to compare

LCP S475 BK210P TAIWAN POLYPLASTICS

60

Form:Granules | Grade:Injection grade

Properties:
Low warpageHigh mobilityheat-resistingFlame retardantenhanceGlass fiber reinforced
Typical Applications:
Electrical applicationsHome appliance components
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Electrical applications | Home appliance components
Properties:Low warpage | High mobility | heat-resisting | Flame retardant | enhance | Glass fiber reinforced

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch23°CISO 179/1eU15kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant ratingUL 94V-0
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Fracture bending strainISO 1782.4%
bending strength23°CISO 178180Mpa
Bending modulus23°CISO 17812000Mpa
Tensile strainBreakISO 527-2/1A/51.8%
tensile strengthBreakISO 527-2/1A/5135Mpa
Tensile modulusISO 527-2/1A12300Mpa
injectionTest ConditionTest MethodTest ResultTest Unit
Spray nozzle temperature355 to 370°C
Processing (melt) temperature360 to 375°C
Mold temperature80 to 120°C
Injection speed中等
Temperature at the front of the material cylinder345 to 365°C
Temperature in the middle of the barrel340 to 360°C
Temperature at the rear of the barrel330 to 350°C
Hopper temperature20 to 40°C
Suggested maximum moisture content0.010%
drying time6.0hr
drying temperature150°C
Back pressure< 3.00Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Linear coefficient of thermal expansionAcross FlowISO 11359-22.5E-5cm/cm/°C
Linear coefficient of thermal expansionFlowISO 11359-21.0E-5cm/cm/°C
Melting temperatureISO 11357-3350°C
Hot deformation temperature8.0 MPa, UnannealedISO 75-2/C213°C
Hot deformation temperature1.8 MPa, UnannealedISO 75-2/A305°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rateFlowISO 294-40.0%
Shrinkage rate横向FlowISO 294-40.40%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Relative permittivity1 MHzIEC 602503.70
Dissipation factor1 MHzIEC 602508.0E-3
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.