Share
Add to compare

PA66 FR50 BK086 DUPONT USA

51

Form:Granules | Grade:Flame retardant grade

Properties:
Flame retardantGlass fiber reinforced
Typical Applications:
Fitness equipmentAutomotive sectorElectrical fieldElectronic fieldElectrical appliances
Product Description
Certificates(1)
Datasheet

Product Description

Typical Applications:Fitness equipment | Automotive sector | Electrical field | Electronic field | Electrical appliances
Properties:Flame retardant | Glass fiber reinforced

Certificates

UL
UL

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch-40°CISO 179/1eU50kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eU50kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU60kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant ratingUL 94V-0
UL flame retardant ratingUL 94V-0
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulusISO 527-210200Mpa
tensile strengthBreakISO 527-2170Mpa
Tensile strainBreakISO 527-22.6%
injectionTest ConditionTest MethodTest ResultTest Unit
drying temperature80°C
Drying time - hot air dryer2.0 to 4.0hr
Suggested maximum moisture content0.20%
Processing (melt) temperature280 to 300°C
Melt Temperature, Optimum290°C
Mold temperature70 to 120°C
Mold Temperature, Optimum100°C
Maintain pressure50.0 to 100Mpa
Maintain pressureDrying Recommendedyes
Hold Pressure Time3.00s/mm
Maximum Screw Tangential Speed12m/min
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.8 MPa, UnannealedISO 75-2/A240°C
Melting temperatureISO 11357-3262°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Shrinkage rate横向FlowISO 294-40.80%
Shrinkage rateFlowISO 294-40.30%
Water absorption rate24 hr, 23°C, 2.00 mmISO 620.60%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityIEC 62631-3-2--ohms
Volume resistivityIEC 62631-3-1> 1.0E+13ohms·m
Dielectric strength2.00 mmIEC 60243-124KV/mm
Compared to the anti leakage trace indexIEC 60112PLC 2
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.