Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
viscosity number | | ISO 307 | 145 cm³/g |
flammability | Test Condition | Test Method | Test Result |
---|
Burning wire flammability index | | IEC 60695-2-12 | -- °C |
Burning wire flammability index | | IEC 60695-2-12 | -- °C |
burning rate | | ISO 3795 | <100 mm/min |
UL flame retardant rating | | IEC 60695-11-10,-20 | V-2 |
UL flame retardant rating | | IEC 60695-11-10,-20 | V-2 |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of simply supported beam without notch | | ISO 179/1eU | NoBreak |
Impact strength of simply supported beam without notch | | ISO 179/1eU | NoBreak |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ISO 527-2/1A/1 | 2900 Mpa |
tensile strength | | ISO 527-2/1A/50 | 80.0 Mpa |
Tensile strain | | ISO 527-2/1A/50 | 4.0 % |
Nominal tensile fracture strain | | ISO 527-2/1A/50 | 10 % |
Flexural modulus | | ISO 178 | 2300 Mpa |
bending strength | | ISO 178 | 100 Mpa |
Bending Strain | | ISO 178 | 6.5 % |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/Bf | 170 °C |
Heat distortion temperature | | ISO 75-2/Af | 60.0 °C |
vicat | | ISO 306/A50 | 210 °C |
vicat | | ISO 306/B50 | 190 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.