PA12 VESTAMID® L LX9102 Altuglas International of Arkema Inc.
0
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Charpy Notched Impact Strength | -30°C,Complete Break | ISO 179/1eA | 5.0 kJ/m² |
| 23°C,Partial Break | ISO 179/1eA | 90 kJ/m² | |
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 无断裂 |
| 23°C | ISO 179/1eU | 无断裂 |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | 3.2mm | UL 94 | HB |
| 1.6mm | UL 94 | HB |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile modulus | ISO 527-2 | 640 MPa | |
| tensile strength | Yield | ISO 527-2 | 32.0 MPa |
| Tensile strain | Break | ISO 527-2 | >50 % |
| Yield | ISO 527-2 | 37 % | |
| tensile strength | Break | ISO 527-2 | 39.0 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 120 °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 55.0 °C | |
| Vicat softening temperature | -- | ISO 306/A | 169 °C |
| -- | ISO 306/B | 136 °C | |
| Melting temperature | ISO 11357-3 | 171 °C | |
| Linear coefficient of thermal expansion | MD:23to55°C | ISO 11359-2 | 1.5E-04 cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Water absorption rate | Saturation,23°C | ISO 62 | 1.5 % |
| Equilibrium,23°C,50%RH | ISO 62 | 0.50 % | |
| Shrinkage rate | MD | ISO 294-4 | 1.4 % |
| TD | ISO 294-4 | 1.5 % | |
| density | 23°C | ISO 1183 | 1.12 g/cm³ |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| insulation resistance | IEC 60167 | 1E+04 ohms | |
| Volume resistivity | IEC 60093 | 1E+04 ohms·cm |
| Supplementary Information | Test Condition | Test Method | Test Result |
|---|---|---|---|
| ISO Shortcut | ISO 1874 | PA12-HIP.EHLZ.22-005 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.