Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO1183 | 1.36 g/cm³ | |
Shrinkage rate | 内部方法 | 0.20 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ISO180/1A | 20 kJ/m² | |
ISO180/1U | 55 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Flexural modulus | ISO178 | 6800 MPa | |
Bending stress | ISO178 | 171 MPa | |
Fracture bending strain | ISO178 | 4.0 % | |
Tensile modulus | ISO527-2/1 | 8700 MPa | |
Tensile stress | Yield | ISO527-2/5 | 125 MPa |
Break | ISO527-2/5 | 123 MPa | |
elongation | ASTMD638 | 2.9 % | |
Break | ISO527-2/5 | 3.0 % |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
ISO75-2/Bf | 217 °C | ||
ISO75-2/Af | 200 °C | ||
ISO11359-2 | 2.7E-05 cm/cm/°C | ||
ISO11359-2 | 1.2E-04 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.