Technical Data Sheet
Basic performance | Test Condition | Test Method | Test Result |
---|
relative density | | ASTM D-792 | 1.65 g/cm |
Shrinkage rate | | ASTM D-955 | 0.3 % |
Other performance | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ASTM D-570 | 0.02 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ASTM D-638 | 135 Mpa |
elongation | Break | ASTM D-638 | 2.2 % |
bending strength | | ASTM D-790 | 180 Mpa |
IZOD impact strength | Notched | ASTM D-256 | 10 KJ/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | ASTM D-149 | 22 Kv/mm |
Volume resistivity | | ASTM D-257 | 1.5×10 Ω﹒cm |
dielectric constant | | ASTM D-150 | 4.9 1KHz |
dielectric loss tangent | | ASTM D-150 | 0.002 1MHz |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ASTM D-648 | 260 ℃ |
Flame retardancy | | UL-94 | V-0 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.