Share
Add to compare

PCTG TX2001(箱装) EASTMAN USA

64

Form:Granules

Properties:
heat-resistingHydrolysis resistanceHigh impact resistanceProcessabilitytransparentChemical resistance
Typical Applications:
Electrical fieldElectronic fieldHousehold appliancesHousehold appliancesHousehold goodsFood service sector
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Electrical field | Electronic field | Household appliances | Household appliances | Household goods | Food service sector
Properties:heat-resisting | Hydrolysis resistance | High impact resistance | Processability | transparent | Chemical resistance

Certificates

No Data...

Technical Data Sheet

optical performanceTest ConditionTest MethodTest ResultTest Unit
transmissivityTotalASTM D100392.0%
turbidityASTM D1003<1.0%
impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of cantilever beam gap23°CASTM D256650J/m
Impact strength of cantilever beam gap-40°CISO 18014kJ/m²
Impact strength of cantilever beam gap23°CISO 18066kJ/m²
Impact strength of cantilever beam gap23°CASTM D4812NoBreak
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile strainYield,23°CISO 527-27.0%
elongationBreak,23°CASTM D638140%
Tensile strainBreak,23°CISO 527-2130%
Bending modulus23°CASTM D7901590Mpa
Bending modulus23°CISO 1781530Mpa
bending strengthYield,23°CASTM D79066.0Mpa
Tensile modulus23°CASTM D6381590Mpa
Tensile modulus23°CISO 527-21620Mpa
tensile strengthYield,23°CASTM D63844.0Mpa
tensile strengthYield,23°CISO 527-245.0Mpa
tensile strengthBreak,23°CASTM D63853.0Mpa
tensile strengthBreak,23°CISO 527-249.0Mpa
elongationYield,23°CASTM D6387.0%
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature0.45MPa,UnannealedASTM D648109°C
Hot deformation temperature1.8MPa,UnannealedASTM D64892.0°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityASTM D7921.17g/cm³
Shrinkage rateMDASTM D9550.50-0.70%
hardnessTest ConditionTest MethodTest ResultTest Unit
Rockwell hardnessR-Sale,23°CASTM D785115
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.