Cellulose, Regenerated 400PUT Innovia Films Ltd.
Typical Applications:
Tape film industrial applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Tape | film | industrial applications |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Friction coefficient | Itself - Static | ASTM D1894 | 0.70 | |
| Itself - Dynamic | ASTM D1894 | 0.50 | ||
| film | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | MD:Yield,28μm | ASTM D882 | 125 | MPa |
| Secant modulus | 1%Secant,TD:28μm | ASTM D882 | >1500 | MPa |
| 1%Secant,MD:28μm | ASTM D882 | >3000 | MPa | |
| film thickness | 28 | µm | ||
| consumption | 27.7μm | Internal Method | 25.0 | m²/kg |
| Oxygen permeability rate | 23°C,28μm,0.0%RH,湿 | ASTMF1927 | 1.00 | cm³/m²/24hr |
| elongation | TD:Break,28μm | ASTM D882 | 70 | % |
| MD:Break,28μm | ASTM D882 | 22 | % | |
| tensile strength | TD:Yield,28μm | ASTM D882 | 70.0 | MPa |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.