PC WONDERLITE® PC-122U CHI MEI CORPORATION
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179 | 60 | kJ/m² |
| Impact strength of cantilever beam gap | 23°C,3.20mm | ASTM D256 | 780 | J/m |
| 23°C | ISO 180/4A | 60 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.75mm | UL 94 | V-2 | |
| 3.0mm | UL 94 | V-2 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Yield | ASTM D638 | 61.6 | MPa |
| Bending modulus | ASTM D790 | 2340 | MPa | |
| ISO 178 | 2400 | MPa | ||
| bending strength | ASTM D790 | 89.8 | MPa | |
| ISO 178 | 90.0 | MPa | ||
| tensile strength | Yield | ISO 527-2/50 | 63.0 | MPa |
| Break | ISO 527-2/50 | 70.0 | MPa | |
| elongation | Break | ASTM D638 | 110 | % |
| Tensile strain | Break | ISO 527-2/50 | 120 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPa,Annealed | ASTM D648 | 143 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 127 | °C | |
| 1.8MPa,Annealed | ISO 75-2/A | 142 | °C | |
| Vicat softening temperature | -- | ISO 306/A50 | 148 | °C |
| -- | ISO 306/B50 | 143 | °C | |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 6.0E-5to8.0E-5 | cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 300°C/1.2kg | ASTM D1238 | 22 | g/10min |
| Melt Volume Flow Rate (MVR) | 300°C/1.2kg | ISO 1133 | 22.0 | cm³/10min |
| Shrinkage rate | ISO 294-4 | 0.50to0.70 | % | |
| density | ASTM D792 | 1.20 | g/cm³ | |
| 23°C | ISO 1183 | 1.20 | g/cm³ | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | M-Scale | ASTM D785 | 77 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.