Unspecified Pushtrusion™ D-GMT LGF34-PP NAT

0

Technical Data Sheet

Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusASTMD6385240 MPa
tensile strengthYieldASTMD63881.4 MPa
elongationBreakASTMD6381.9 %
Flexural modulusASTMD7904830 MPa
bending strengthASTMD790115 MPa
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTMD256430 J/m
Suspended wall beam without notch impact strengthASTMD256890 J/m
Dynatup-TotalEnergy24.8 J
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.