Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ISO 62 | 0.15 % |
Water absorption rate | | ISO 62 | 0.4 % |
Shrinkage rate | | ISO 294-4 | 1.0 % |
Shrinkage rate | | ISO 294-4 | 0.35 % |
density | | ISO 1183 | 1.45 g/cm |
MediumDensity | | | 1.26 g/cm³ |
Ejection Temperature | | | 170 °C |
SpecificHeatCapacity of Melt | | | 1860 J/kg/°C |
density | | ISO1183 | 1.45 g/cm³ |
Shrinkage rate | | ISO294-4 | 1.1 % |
Shrinkage rate | | ISO294-4 | 0.30 % |
Water absorption rate | | ISO62 | 0.40 % |
Water absorption rate | | ISO62 | 0.15 % |
ThermalConductivityofMelt | | | 0.25 W/m/K |
flammability | Test Condition | Test Method | Test Result |
---|
Burning rate 3 | | ISO3795 | 28 mm/min |
UL flame retardant rating | | UL94 | HB |
UL flame retardant rating | | UL94 | HB |
UL flame retardant rating | | IEC60695-11-10,-20 | HB |
UL flame retardant rating | | IEC60695-11-10,-20 | HB |
Limiting Oxygen Index | | ISO4589-2 | 19 % |
FMVSS flammability | | FMVSS302 | B |
Fogging-G-value | | ISO6452 | 1E-04 g |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
Emissions of Organic Compounds | | VDA277 | 140 µgC/g |
Odor | | VDA270 | 3.00 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Charpy notch impact strength | | ISO 179 | 7.5 KJ/m |
Fracture point tensile stress | | ISO 527-1, -2 | 120 MPa |
Fracture point tensile strain | | ISO 527-1, -2 | 3.2 % |
Tensile modulus | | ISO 527-1, -2 | 7400 MPa |
Flexural modulus | | ISO 178 | 6200 MPa |
bending strength | | ISO 178 | 180 MPa |
Non notched impact strength | | ISO 180 | 44 KJ/m |
Notch impact strength | | ISO 180 | 8 KJ/m |
Tensile creep modulus | | ISO 899-1 | 7200 MPa |
Tensile creep modulus | | ISO 899-1 | 5600 MPa |
Charpy non notched impact strength | | ISO 179 | 54 KJ/m |
Charpy non notched impact strength | | ISO 179 | 56 KJ/m |
Charpy notch impact strength | | ISO 179 | 9.8 KJ/m |
Flexural modulus | | ISO178 | 6500 Mpa |
Bending stress | | ISO178 | 180 Mpa |
Tensile modulus | | ISO527-2 | 7000 Mpa |
Tensile stress | | ISO527-2 | 120 Mpa |
Tensile strain | | ISO527-2 | 3.2 % |
TensileCreepModule | | ISO899-1 | 7200 Mpa |
Tensile creep modulus | | ISO899-1 | 5600 Mpa |
Other performance | Test Condition | Test Method | Test Result |
---|
Limiting Oxygen Index | | ISO 4589-1, -2 | 19 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO179/1eA | 9.0 kJ/m² |
Charpy Notched Impact Strength | | ISO179/1eA | 8.0 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 55 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 60 kJ/m² |
Impact strength of cantilever beam gap | | ISO180/1A | 8.0 kJ/m² |
Impact strength of cantilever beam gap | | ISO180/1A | 9.0 kJ/m² |
| | ISO180/1U | 60 kJ/m² |
| | ISO180/1U | 60 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
| | IEC60250 | 3.60 |
Dissipation Factor | | IEC60250 | 1.2E-03 |
Dissipation Factor | | IEC60250 | 0.019 |
CTI | | IEC60112 | 350 V |
Surface Resistivity | | IEC60093 | 1E+15 ohms |
Volume resistivity | | IEC60093 | >1.0E+15 ohms·cm |
dielectric strength | | IEC60243-1 | 29 KV/mm |
| | IEC60250 | 4.00 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ISO 11359-1, -2 | 0.000100 cm/cm/℃ |
| | ISO 11359-1, -2 | 0.000040 cm/cm/℃ |
| | ISO 75B-1, -2 | 220 ℃ |
| | ISO 75B-1, -2 | 204 ℃ |
UL flame retardant rating | | | UL 94 HB |
UL flame retardant rating | | | UL 94 HB |
UL flame retardant rating | | | UL 94 HB |
melting temperature | | ISO 3146 | 225 ℃ |
| | ISO75-2/B | 220 °C |
| | ISO75-2/A | 204 °C |
vicat | | ISO306/B50 | 210 °C |
melting temperature | | ISO11357-3 | 224 °C |
| | ISO11359-2 | 4E-05 cm/cm/°C |
| | ISO11359-2 | 1E-04 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.