PC S-1000R BK MITSUBISHI ENGINEERING JAPAN
54
Form:Granules | Grade:Injection grade
Properties:
High transparency
Typical Applications:
Bottle capCastersOptical applicationsHome appliance componentsAutomotive Applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Bottle cap | Casters | Optical applications | Home appliance components | Automotive Applications |
| Properties: | High transparency |
Certificates
No Data...
Technical Data Sheet
| Other performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| UL flame retardant rating | 1.60mm | UL 94 | V-2 | |
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 24hr | ASTM D-570 | 0.24 | % |
| melt mass-flow rate | 300℃/1.2kg | ASTM D-1238 | 8.5 | g/10min |
| Shrinkage rate | MD,3.00mm | ASTM D-955 | 0.6 | % |
| density | ASTM D-792 | 1.20 | g/cm³ | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Dart impact | 3.20mm | ASTM D-3029 | > 85.0 | J |
| Impact strength of cantilever beam gap | 3.20mm | ASTM D-256 | 900 | J/m |
| bending strength | 3.20mm | ASTM D-790 | 90.0 | Mpa |
| Bending modulus | 3.20mm | ASTM D-790 | 2350 | Mpa |
| elongation | Break,3.20mm | ASTM D-638 | 120 | % |
| tensile strength | 3.20mm | ASTM D-638 | 65 | Mpa |
| Rockwell hardness | R | ASTM D-785 | 123 | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed,6.4mm | ASTM D-648 | 138 | °C |
| Linear coefficient of thermal expansion | Flow | ASTM D-696 | 6.5E-05 | cm/cm/℃ |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric constant | ASTM D-150 | 2.85 | ||
| Volume resistivity | ASTM D-257 | 2.1E+16 | ohm·cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.