PC OP - PC - Unfilled 1518-FDA Oxford Performance Materials, Inc.

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTM D7921.20 g/cm³
melt mass-flow rateASTM D123817 g/10min
Shrinkage rateASTM D9550.50to0.70 %
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94V-2
UL flame retardant ratingUL 94V-2
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gapASTM D256690 J/m
Dart impactASTM D302936.2 J
Mechanical propertiesTest ConditionTest MethodTest Result
tensile strength YieldASTM D63862.1 MPa
tensile strength BreakASTM D63868.9 MPa
Flexural modulusASTM D7902310 MPa
bending strengthASTM D79095.8 MPa
Thermal performanceTest ConditionTest MethodTest Result
Heat distortion temperatureASTM D648132 °C
Heat distortion temperatureASTM D648127 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.