Share
Original TDS
Add to Compare

PP AP3AW EXXONMOBIL SINGAPORE

59

Form:Granules | Grade:Injection grade

Properties:
Low warpageHigh rigidityHigh impact resistanceMiddle flowLight resistance
Typical Applications:
Battery boxEngine hood partsAutomotive sectorApplication in the automotive fieldParts under the hood of a car
Product Description
Certificates(2)
Datasheet

Product Description

Typical Applications:Battery box | Engine hood parts | Automotive sector | Application in the automotive field | Parts under the hood of a car
Properties:Low warpage | High rigidity | High impact resistance | Middle flow | Light resistance

Certificates

UL
UL
TDS

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Dart impact-29°C,3.18mmASTM D542018.1J
Impact strength of cantilever beam gap23°CISO 180/1A8.8kJ/m²
Impact strength of cantilever beam gap-18°CISO 180/1A4.5kJ/m²
Impact strength of cantilever beam gap-40°CISO 180/1A3.4kJ/m²
Impact strength of cantilever beam gap23°CASTM D256A90J/m
Impact strength of cantilever beam gap-18°CASTM D256A35J/m
Charpy Notched Impact Strength23°CISO 179/1eA9.9kJ/m²
Charpy Notched Impact Strength0°CISO 179/1eA4.9kJ/m²
Charpy Notched Impact Strength-20°CISO 179/1eA3.9kJ/m²
Charpy Notched Impact Strength-30°CISO 179/1eA3.3kJ/m²
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Bending modulus--6ISO 1781340Mpa
Bending modulus1%Secant5ASTM D790B1520Mpa
Bending modulus1%Secant4ASTM D790A1340Mpa
elongationYieldISO 527-2/505.7%
elongationYield3ASTM D6385.6%
tensile strengthYieldISO 527-2/5025.7Mpa
tensile strengthYield3ASTM D63827.1Mpa
Tensile modulusISO 527-2/11500Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A53.4°C
Hot deformation temperature0.45MPa,AnnealedASTM D648116°C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/Bf92.5°C
Hot deformation temperature0.45MPa,UnannealedASTM D64899.4°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
melt mass-flow rate230°C/2.16kgASTM D123810g/10min
hardnessTest ConditionTest MethodTest ResultTest Unit
Rockwell hardnessASTM D78596
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.