Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Shrinkage rate | | ISO 294-4 | 0.50-0.80 % |
Shrinkage rate | | ISO 294-4 | 0.25-0.50 % |
Basic performance | Test Condition | Test Method | Test Result |
---|
density | | ISO 1183/B | 1.26 g/cm |
Water absorption rate | | ISO 62 | 0.22 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
bending strength | | ISO 178 | 215 Mpa |
Charpy Notched Impact Strength | | ISO 179 | 7.00 KJ/m |
Impact strength of simply supported beam without notch | | ISO 179 | 49.0 KJ/m |
Impact strength of cantilever beam gap | | ISO 180 | 7.00 KJ/m |
Suspended wall beam without notch impact strength | | ISO 180 | 43.0 KJ/m |
Tensile stress | | ISO 527-2 | 145 Mpa |
fracture strain | | ISO 527-2 | 3.0 % |
Flexural modulus | | ISO 178 | 7300 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Volume resistivity | | IEC 60093 | 3.1E+15 ohm.cm |
dielectric constant | | IEC 60250 | 3.100 |
Dielectric loss | | IEC 60250 | 0.0340 |
dielectric strength | | IEC 60243-1 | 25.00 KV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/A | 240 °C |
UL flame retardant rating | | UL 94 | HB |
Heat distortion temperature | | ISO 75-2/B | 260 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.