PC 2807 550115 COVESTRO SHANGHAI
69
Form:Granules
Properties:
Weather resistanceUV resistanceMedium viscosity
Typical Applications:
Electrical fieldElectronic fieldAutomotive sectorIndustrial componentscurrency
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical field | Electronic field | Automotive sector | Industrial components | currency |
| Properties: | Weather resistance | UV resistance | Medium viscosity |
Certificates
No Data...
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| turbidity | 3000μm | ISO 14782 | <0.80 | % |
| transmissivity | 4000μm | ISO 13468-2 | 87.0 | % |
| Refractive index | ISO 489 | 1.586 | ||
| transmissivity | 1000μm | ISO 13468-2 | 89.0 | % |
| 3000μm | ISO 13468-2 | 88.0 | % | |
| 2000μm | ISO 13468-2 | 89.0 | % | |
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Charpy Notched Impact Strength | 23°C,Partial Break | ISO 7391 | 75 | kJ/m² |
| -30°C,Complete Break | ISO 7391 | 14 | kJ/m² | |
| Impact strength of cantilever beam gap | 23°C,Partial Break | ISO 7391 | 70 | kJ/m² |
| -30°C,Complete Break | ISO 7391 | 15 | kJ/m² | |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | NoBreak | |
| -30°C | ISO 179/1eU | NoBreak | ||
| -60°C | ISO 179/1eU | NoBreak | ||
| Multi axis Instrumented Peak Impact Force | 23°C | ISO 6603-2 | 5400 | N |
| -30°C | ISO 6603-2 | 6300 | N | |
| Multi axis Instrumented Impact Energy | -30°C | ISO 6603-2 | 65.0 | J |
| 23°C | ISO 6603-2 | 60.0 | J | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Needle flame test | MethodF:2.00mm | IEC 60695-11-5 | 1.0 | min |
| MethodK:2.00mm | IEC 60695-11-5 | 0.1 | min | |
| MethodF:3.00mm | IEC 60695-11-5 | 2.0 | min | |
| MethodK:1.50mm | IEC 60695-11-5 | 0.1 | min | |
| GlowWireTest | 3.00mm | EDFHN60E.02 | 750 | °C |
| Needle flame test | MethodF:1.50mm | IEC 60695-11-5 | 1.0 | min |
| UL flame retardant rating | 2.5mm | UL 94 | HB | |
| 0.75mm | UL 94 | V-2 | ||
| Burning wire flammability index | 0.75mm | IEC 60695-2-12 | 850 | °C |
| 1.5mm | IEC 60695-2-12 | 850 | °C | |
| 3.0mm | IEC 60695-2-12 | 930 | °C | |
| Hot filament ignition temperature | 0.75mm | IEC 60695-2-13 | 875 | °C |
| 1.5mm | IEC 60695-2-13 | 875 | °C | |
| 3.0mm | IEC 60695-2-13 | 875 | °C | |
| Extreme Oxygen Index | ISO 4589-2 | 28 | % | |
| Needle flame test | MethodK:3.00mm | IEC 60695-11-5 | 0.2 | min |
| SelfIgnition | ASTM D1929 | 550 | °C | |
| FlashIgnitionTemperature | ASTM D1929 | 480 | °C | |
| GlowWireTest | 1.50mm | EDFHN60E.02 | 750 | °C |
| Burning rate - US-FMVSS | >1.00mm | ISO 3795 | passed | |
| ApplicationofFlamefromSmallBurner MethodKandF | 2.00mm | DIN 53438-1,-3 | K1.F1 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Yield,23°C | ISO 527-2/50 | 6.1 | % |
| Break,23°C | ISO 527-2/50 | 130 | % | |
| tensile strength | Yield,23°C | ISO 527-2/50 | 66.0 | Mpa |
| Tensile creep modulus | 1000hr | ISO 899-1 | 1900 | Mpa |
| 1hr | ISO 899-1 | 2200 | Mpa | |
| Nominal tensile fracture strain | 23°C | ISO 527-2/50 | >50 | % |
| tensile strength | Break,23°C | ISO 527-2/50 | 70.0 | Mpa |
| bending strength | 3.5%Strain,23°C | ISO 178 | 74.0 | Mpa |
| Bending modulus | 23°C | ISO 178 | 2400 | Mpa |
| bending strength | 23°C | ISO 178 | 98.0 | Mpa |
| Bending strain | 23°C | ISO 178 | 7.0 | % |
| Tensile modulus | 23°C | ISO 527-2/1 | 2400 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI Imp | 1.5mm | UL 746 | 115 | °C |
| RTI Str | 1.5mm | UL 746 | 125 | °C |
| Vicat softening temperature | -- | ISO 306/B120 | 145 | °C |
| -- | ISO 306/B50 | 143 | °C | |
| Glass transition temperature | ISO 11357-2 | 144 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 124 | °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 136 | °C | |
| RTI Elec | 1.5mm | UL 746 | 125 | °C |
| thermal conductivity | 23°C | ISO 8302 | 0.20 | W/m/K |
| Linear coefficient of thermal expansion | TD:23to55°C | ISO 11359-2 | 6.5E-05 | cm/cm/°C |
| MD:23to55°C | ISO 11359-2 | 6.5E-05 | cm/cm/°C | |
| Ball Pressure Test | 135°C | IEC 60695-10-2 | Pass | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | 23°C | ISO 1183 | 1.20 | g/cm³ |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.12 | % |
| Saturation,23°C | ISO 62 | 0.30 | % | |
| Shrinkage rate | MD:2.00mm3 | ISO 294-4 | 0.65 | % |
| TD:2.00mm3 | ISO 294-4 | 0.70 | % | |
| MD | ISO 2577 | 0.60-0.80 | % | |
| Melt Volume Flow Rate (MVR) | 300°C/1.2kg | ISO 1133 | 9.00 | cm3/10min |
| Shrinkage rate | TD | ISO 2577 | 0.60-0.80 | % |
| Apparent density | ISO 60 | 0.66 | g/cm³ | |
| melt mass-flow rate | 300°C/1.2kg | ISO 1133 | 10 | g/10min |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | 1E+16 | ohms | |
| Compared to the anti leakage trace index | SolutionA | IEC 60112 | V | |
| Dielectric strength | 23°C,1.00mm | IEC 60243-1 | 34 | KV/mm |
| Relative permittivity | 23°C,100Hz | IEC 60250 | 3.10 | |
| 23°C,1MHz | IEC 60250 | 3.00 | ||
| Dissipation factor | 23°C,100Hz | IEC 60250 | 5E-04 | |
| 23°C,1MHz | IEC 60250 | 9E-03 | ||
| Volume resistivity | 23°C | IEC 60093 | 1E+16 | ohms·cm |
| Compared to the anti leakage trace index | SolutionB | IEC 60112 | PLC 4 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Ball Pressure Test | ISO 2039-1 | 115 | Mpa | |
| film | Test Condition | Test Method | Test Result | Test Unit |
| Water vapor permeability | 23°C,85%RH,100μm | ISO 15106-1 | 15 | g/m²/24hr |
| GasPermeation | CarbonDioxide:23°C,25.4μm | ISO 2556 | 16900 | cm³/m²/bar/24hr |
| Oxygen:23°C,100.0μm | ISO 2556 | 650 | cm³/m²/bar/24hr | |
| Oxygen:23°C,25.4μm | ISO 2556 | 2760 | cm³/m²/bar/24hr | |
| Nitrogen:23°C,100.0μm | ISO 2556 | 120 | cm³/m²/bar/24hr | |
| Nitrogen:23°C,25.4μm | ISO 2556 | 510 | cm³/m²/bar/24hr | |
| CarbonDioxide:23°C,100.0μm | ISO 2556 | 3800 | cm³/m²/bar/24hr | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| Electrolytic corrosion | 23°C | IEC 60426 | A1 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.